Main |
range of product |
OsiSense XT |
sensor type |
Capacitive proximity sensor |
product specific application |
Detection of insulated or conductive materials
Animal feeding |
sensor name |
XT2 |
sensor design |
Cylindrical M30 |
size |
100 mm |
body type |
Fixed |
detector flush mounting acceptance |
Non flush mountable |
material |
Plastic |
enclosure material |
Plastic |
type of output signal |
Discrete |
wiring technique |
2-wire |
[Sn] nominal sensing distance |
15 mm |
discrete output function |
1 NO or 1 NC programmable |
output type circuit |
AC
DC |
electrical connection |
Screw clamp terminal |
[Us] rated supply voltage |
24...240 V AC 50...60 Hz |
delay response |
< 10 ms |
IP degree of protection |
IP65 double insulation conforming to IEC 60529 |
Complementary |
ISO thread |
M30 x 1.5 |
face detection |
Frontal |
[Sa] assured operating distance |
0...11 mm |
adjustment zone |
0...17 mm |
differential travel |
< 1...15 % Sr |
repeat accuracy |
< 5 % Sr |
cable entry |
1 entry incorporating cable gland, cable outer diameter: 7...13 mm |
status LED |
1 LED (yellow) for output state indication |
supply voltage limits |
20...265 V AC |
residual current |
< 120 mA (open state) |
frequency switching |
<= 40 Hz |
voltage drop |
< 2 V (closed) |
current consumption |
< 3 mA |
delay first up |
< 100 ms |
delay recovery |
< 10 ms |
maximum current switching |
300 mA |
marking |
CE |
setting-up |
Sensitivity by potentiometer |
threaded length |
45 mm |
length |
100 mm |
product weight |
0.1 kg |
Environment |
standards |
EN/IEC 60947-5-2 |
product certifications |
cULus |
ambient air temperature for operation |
-20...70 °C |
ambient air temperature for storage |
Від -40 до 85 °C |
vibration resistance |
10 gn amplitude = 1 mm (10...55 Hz) conforming to IEC 60068-2-6 |
shock resistance |
30 gn (duration = 11 ms) conforming to IEC 60068-2-27 |
resistance to discharge electrostatic |
4 kV (contact) conforming to IEC 61000-4-2
8 kV (air) conforming to IEC 61000-4-2 |
resistance to electromagnetic fields |
3 V/m conforming to IEC 61000-4-3 |
resistance to fast transients |
2 kV conforming to IEC 61000-4-4 |
Offer Sustainability |
Sustainable offer status |
Not Premium Green product |
RoHS (date code: YYWW) |
Compliant - since 0918 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity |